Sequence Valve – Atmospherically referenced
Atmospherically referenced direct-acting sequence valves (2 port) with reverse-flow check have uses as follows:
- Supply a secondary circuit with flow once the pressure at port 1 exceeds the valve setting
- Suitable for use in load holding applications
Specifications of Atmospherically referenced direct-acting sequence valves with reverse-flow check valves:
- Approximately 1 drop of fluid will pass into the vented spring chamber every 4000 cycles
Special Features of Atmospherically referenced direct-acting sequence valves with reverse-flow check valves:
- These valves incorporate an integral check valve to provide reverse flow from port 2 to port 1
- Pressure setting of valve controls the pressure at port 1 relative to the atmospheric vent.
- Drain line is not required